Appliance Coupler Number of Standard Sheet for |
Infomations |
Appliance Inlet(male) |
Connector(female) |
C2
|
C1
|
Rated current of appliance coupler (A) |
0.2 |
Class of equipment |
II |
Maximum temperature of appliance inlet |
70℃ |
Rewirable construction allowed |
No |
Lightest type allowed |
60227 IEC 41 |
Minimum cross-section (mm) |
—(1) |
Standard sheet of IEC 60083 |
A 1-15 , B , C 5 |
C6
|
C5
|
Rated current of appliance coupler (A) |
2.5 |
Class of equipment |
I |
Maximum temperature of appliance inlet |
70℃ |
Rewirable construction allowed |
No |
Lightest type allowed |
60227 IEC 52 |
Minimum cross-section (mm) |
0.75 |
Standard sheet of IEC 60083 |
A 5-15 , B 2 , C 2b , C 4 |
C8
|
C7
|
Rated current of appliance coupler (A) |
2.5 |
Class of equipment |
II |
Maximum temperature of appliance inlet |
70℃ |
Rewirable construction allowed |
No |
Lightest type allowed |
60227 IEC 52 |
Minimum cross-section (mm) |
0.75(2) |
Standard sheet of IEC 60083 |
A 1-15 , B 2 , C 5 , C 6 |
C10
|
C9
|
Rated current of appliance coupler (A) |
6 |
Class of equipment |
II |
Maximum temperature of appliance inlet |
70℃ |
Rewirable construction allowed |
No |
Lightest type allowed |
60227 IEC 52 |
Minimum cross-section (mm) |
0.75 |
Standard sheet of IEC 60083 |
A 1-15 , B 2 , C 6 |
C14
|
C13
|
Rated current of appliance coupler (A) |
10 |
Class of equipment |
I |
Maximum temperature of appliance inlet |
70℃ |
Rewirable construction allowed |
Yes |
Lightest type allowed |
60227 IEC 53 or 60245 IEC 53 |
Minimum cross-section (mm) |
0.75(3) |
Standard sheet of IEC 60083 |
A 5-15 , B 2 , C 2b , C 3b , C 4 |
C16
|
C15
|
Rated current of appliance coupler (A) |
10 |
Class of equipment |
I |
Maximum temperature of appliance inlet |
120℃ |
Rewirable construction allowed |
Yes |
Lightest type allowed |
60245 IEC 53 or 60245 IEC 51 |
Minimum cross-section (mm) |
0.75(3) |
Standard sheet of IEC 60083 |
A 5-15 , B 2 , C 2b , C 3b , C 4 |
C16A
|
C15A
|
Rated current of appliance coupler (A) |
10 |
Class of equipment |
I |
Maximum temperature of appliance inlet |
155℃ |
Rewirable construction allowed |
Yes |
Lightest type allowed |
60245 IEC 53 or 60245 IEC 51 |
Minimum cross-section (mm) |
0.75(3) |
Standard sheet of IEC 60083 |
A 5-15 , B 2 , C 2b , C 3b , C 4 |
C18
|
C17
|
Rated current of appliance coupler (A) |
10 |
Class of equipment |
II |
Maximum temperature of appliance inlet |
70℃ |
Rewirable construction allowed |
No |
Lightest type allowed |
60227 IEC 53 or 60245 IEC 53 |
Minimum cross-section (mm) |
0.75(3) |
Standard sheet of IEC 60083 |
A 1-15 , B 2 , C 6 |
C20
|
C19
|
Rated current of appliance coupler (A) |
16 |
Class of equipment |
I |
Maximum temperature of appliance inlet |
70℃ |
Rewirable construction allowed |
Yes |
Lightest type allowed |
60227 IEC 53 or 60245 IEC 53 |
Minimum cross-section (mm) |
1(3) |
Standard sheet of IEC 60083 |
A 5-15 , B 2 , C 2b , C 3b , C 4 |
C22
|
C21
|
Rated current of appliance coupler (A) |
16 |
Class of equipment |
I |
Maximum temperature of appliance inlet |
155℃ |
Rewirable construction allowed |
Yes |
Lightest type allowed |
60245 IEC 53 or 60245 IEC 51 |
Minimum cross-section (mm) |
1(3) |
Standard sheet of IEC 60083 |
A 5-15 , B 2 , C 2b , C 3b , C 4 |
C24
|
C23
|
Rated current of appliance coupler (A) |
16 |
Class of equipment |
II |
Maximum temperature of appliance inlet |
70℃ |
Rewirable construction allowed |
No |
Lightest type allowed |
60227 IEC 53 or 60245 IEC 53 |
Minimum cross-section (mm) |
1(3) |
Standard sheet of IEC 60083 |
A 1-15 , B 2 , C 6 |
1. (1)Only for small hand-held appliances, in length not exceeding 2 m, if allowed by the relevant appliance standard.
2. (2)0,5 mm2 is allowed for lengths not exceeding 2 m.
3. (3)If the cord has a length exceeding 2 m or is of the retractable coiled (pre-coiled) type, nominal cross-sectional areas shall be
– 1 mm2 for 10 A connectors
– 1.5 mm2 for 16 A connectors |